Showing 49–56 of 56 results

Heat Reclaim Units – HMD

Condenser

1/2HP – 1140 RPM
DIRECT DRIVE MOTORS, SMOOTH TUBES

CityQuiet version available

SmartPower version available

ZeroLeak Certified

Condensers & Heat Reclaim Units

Heat Reclaim Units – HCD

Condenser

1/4HP – 825 RPM

DIRECT DRIVE MOTORS, SMOOTH TUBES

ZeroLeak Certified

Condensers & Heat Reclaim Units

Fluid Coolers – FCD / FMD / FLD / FLV / FND / FNV / FVD / FVV

The dramatic increase in city water and sewage rates, along with the costly operation of evaporative cooling towers, have created a demand for closed circuit cooling systems.

RefPlus offers a complete line of Dry Type Fluid Coolers for both commercial (air conditioning) and industrial (process cooling) applications. Our Dry Type Fluid Coolers can be designed to meet virtually any heat load – from as small as 10,000 Btu/hr to over 6 million Btu/hr.

RefPlus Dry Type Fluid Coolers are completely sealed, thereby requiring no make-up water or expensive chemical treatment. As these coolers are a closed circuit design, they conserve both water and energy, and are environmentally friendly. Most importantly, our systems are rated and sized specifically according to the customer’s site and requirements.

For information, please contact Sales department.

CityQuitet version available

SmartPower version available

ZeroLeak Certified

Fluid Coolers

Opti-Mist Plus

How does it work?

The Opti-Mist Plus system uses a natural air cooling process by evaporating a small amount of water to pre-cool air entering a heat exchanger. A system of headers with atomizing nozzles generates a fog of ultra-fine water droplets in the entering air of the unit. A modulating control (50 to 100%) will adjust the air cooling to the job requirement reducing the amount of water used.

Benefits

  • Pre-cooling the entering air is like reducing the ambient condition at the unit.
  • The Opti-Mist Plus system reduces the size of cooling units while still meeting the cooling requirements of the application.
  • The Opti-Mist Plus system saves energy by reducing the condensing temperature and the fluid temperature. The fluid can be cooled at a temperature close to the ambient temperature.
  • Allows CO2 systems to operate in sub-critical condition for longer hours or more efficiently in a warmer climate.
Adiabatic Cooling System

Commercial and Industrial free standing coils

Standard and Custom Construction

Direct Expansion Evaporator Coils (DX)

Refrigerant Condenser and Heat Reclaim Coils

Chilled and Hot Water Coils

Booster Coils

SmartPower version available

ZeroLeak Certified

Steam and Steam Distributing Coils

Free Standing Coils

Indoor and Outdoor air handling units

The RefPlus Air Handling Units have a unique modular design based on an aluminium structural framing offering unlimited possibilities. The Central Station (CS Series) has the versatility to suit any air treatment requirement such as filtration, heating, cooling, energy recovery, mixing, economizer, multi-zone control and dehumidification. The CS Series offers a complete range of standard modules that are easily arranged into many complex custom systems.

CityQuiet version available

SmartPower version available

Certified ZeroLeak

Central Stations

Our CO2 (R744) Product Range

Evaporators type for refrigerated  cabinet direct expansion mode  and recirculation.

Type of  evaporators for cold chamber direct expansion mode and recirculation.

Gas coolers for facilities operating in transcritical system for design pressure of 1740psi.

Heat recovery ensuring an efficient performance due to high temperatures of CO2.

Design pressure: up to 1740psi (120bar).

CityQuiet version available

SmartPower version available

ZeroLeak Certified

CO2 Units

E-DryPlus

The E-DryPlus is a small dimension desiccant dehumidifier mainly for skating and curling rinks. The regeneration is modular for a maximum energy saving. It is an electric heater combined with an optional refrigeration glycol or steam heat recovery coil. It supplies the minimum energy to meet the job requirement. A space is provided for the installation of a heat recovery coil. Optional glycol or steam coil can also replace the electric heater, the PLC provides a 0-10v signal to control a modulating valve.

The E-DryPlus controls are complete with a humidity sensor and a modulating capacity for the regeneration process. A PLC control analyses the dehumidification requirement and adjusts the regeneration temperature according to the water removal requirement and meet the job demand. The control system saves energy by using the minimum regeneration temperature.

The maximum regeneration capacity is 30Kw. This can be a combination of an electric heater 10, 20 or 30 Kw combined with a heat recovery coil of 10 or 20 Kw.

The electric heater can be replaced with a modulating 20 to 30 Kw glycol or steam heating element.

The standard unit does not use any refrigerant. The exception is an optional refrigerant heat reclaim coil. Those units with the optional glycol recovery coil are ideal for LEED buildings.

ZeroLeak Certified

E-DryPlus